地源热泵空调系统热平衡及土壤温度分布实验研究  被引量:15

The Experimental Study on Heat Balance and Soil Temperature Distribution of Ground Source Heat Pump of Air-Conditioning System

在线阅读下载全文

作  者:杨燕[1] 翟晓强[1] 余鑫[1] 王如竹[1] 

机构地区:[1]上海交通大学制冷与低温工程研究所,上海200240

出  处:《工程热物理学报》2011年第11期1819-1822,共4页Journal of Engineering Thermophysics

基  金:上海市科委科研计划项目(No.07DZ12021)

摘  要:本文利用地源热泵空调系统的全年运行实验结果,研究了地埋管换热器与周围土壤的热量交换以及土壤的温度变化。实验结果与理论计算表明,由于采用热回收技术,该系统可减少33 7%的热量排放。连续运行一年后,土壤的平均温升为0.7℃,解决了夏热冬冷地区地源热泵空调系统的土壤热平衡问题。This paper uses operating results of the whole year of the ground source heat pump of air-conditioning system, and studies the heat transfer between the ground heat exchanger with the surrounding soil. At the same time, the paper studies the temperature distribution of the heat exchanger's surrounding soil. The experimental and theoretical results show that as the system utilizes the heat recovery technology, the system reduces about 33.7% heat which discharges to the ground. After the system operates one year continuously, the average temperature of the soil rises 0.7℃. The technology has solved the problem of the soil heat balance in the hot summer and cold winter zone.

关 键 词:地源热泵 热平衡 土壤温度 

分 类 号:TK529[动力工程及工程热物理—热能工程]

 