检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江省慈溪市疾病预防控制中心,浙江慈溪315300
出 处:《中国卫生检验杂志》2011年第10期2397-2398,共2页Chinese Journal of Health Laboratory Technology
摘 要:目的:建立了空气中乙醇胺、三甲胺的离子色谱测定方法。方法:以20 mmol/L硫酸水溶液作为吸收液,以1.0 L/min流量采样20 min;采样后的溶液以甲基磺酸(MSA)和乙腈混合淋洗,Dionex IonPac SCS1柱分离,非抑制型电导检测。结果:乙醇胺和三甲胺在0μg/ml~200μg/ml范围相关系数均大于0.999,检出限分别为1.9μg/L和2.4μg/L,回收率分别为101.6%和99.0%,RSD均小于5.0%。结论:将该方法应用于实际空气样品的检测,结果满意。Objective:To establish a sensitive method for the determination of ethanolamine and trimethylamine(TMA) in air by ion chromatography with non-suppressed conductivity detection.Methods: Ethanolamine and trimethylamine in air was sampled at a rate of 1.0 L/min and absorbed in 20 mmol/L H2SO4 solution.The separation was performed on an IonPac SCS 1 analytical column(250 mm × 4.0 mm i.d.) and an IonPac SCG 1 guard column(50 mm×4.0 mm i.d.) by using methanesulfonic acid(MSA) as eluent with acetonitrile as organic modifier.Results: The linear range of the method was 0 μg/ml^200 μg/ml for ethanolamine and trimethylamine both with correlation coefficients more than 0.999,the limits of detection were 1.9 μg/L for ethanolamine and 2.4 μg/L for trimethylamine,respectively.The recoveries were 101.6% for ethanolamine and 99.0% for trimethylamine,with RSDs less than 5.0%.Conclusion: The developed method was satisfied for the determination of ethanolamine and trimethylamine in air.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229