马钢1号高炉定修快速恢复操作的经验  

Quick Operation Recovery after Scheduled Maintenance at Masteel's No.1 Blast Furnace

在线阅读下载全文

作  者:蒋裕[1] 徐川[1] 张兴锋[1] 程旺生[1] 

机构地区:[1]马鞍山钢铁股份有限公司

出  处:《安徽冶金》2011年第3期22-24,54,共4页Anhui Metallurgy

摘  要:根据马钢1#2500m3高炉定修时间长的特点,通过不断调整和完善休复风方案,即合理添加休风料、合理控制复风后炉料负荷、风速以及捅风口速度、强化炉前出铁等措施,实现了高炉定修后炉况的快速恢复,并结合两个案例详细地进行阐述,总结了快速恢复中的经验及特点。Based on the long duration of scheduled maintenance of Masteel's No. 1 2500m3 blast furnace and through continuous adjustment and improvement of blast stop and re-blowing plans, normal operation conditions were resumed soon after re-blowing. The stop and re-blowing plans included measures such as proper addition of downtime materials, proper control of re-blowing charge load, blast rate and tuyere poking speed and intensifying tapping opera- tion. This practice is described in detail with two real cases. Experiences in quick operation recovery and characteris- tics of the practice are summarized.

关 键 词:高炉 定修 快速恢复 

分 类 号:TF538.63[冶金工程—钢铁冶金]

 