Preliminary study of depth of interaction measurement for a PET detector  被引量:1

Preliminary study of depth of interaction measurement for a PET detector

在线阅读下载全文

作  者:廖燕飞 章志明 李道武 帅磊 单保慈 黄先超 刘军辉 陈研 王英杰 刘双全 王培林 魏书军 魏龙 

机构地区:[1]Key Laboratory of Nuclear Analysis Techniques,Institute of High Energy Physics,Chinese Academy of Sciences [2]Beijing Engineering Research Center of Radiographic Techniques and Equipment [3]Graduate University of Chinese Academy of Sciences

出  处:《Chinese Physics C》2011年第11期1070-1073,共4页中国物理C(英文版)

基  金:Supported by National Natural Science Foundation of China (10805049, 10775149)

摘  要:In this work we studied the feasibility of detecting the depth of interaction (DOI) with two layers of crystal arrays of LYSO and BGO scintillators coupled to a position-sensitive photomultiplier tube (PS-PMT) R8900-C12. A front-end electronics was designed, with which we got different pulse shapes for different crystals to obtain depth information. With the double integration method, we got the DOI histogram of a divided integration ratio of two crystals as the standard to determine the layer-of-interaction. The DOI accuracy, measured by scanning a 22Na slit source along the side of the module, was 98% for the LYSO layer and 95% for the BGO layer. The energy resolution at 511keV was 13.1% for LYSO and 17.1% for BGO. We obtained good crystal separation in 2D position histograms of both layers. These results could be useful in the manufacture of PET scanners with high spatial resolutions.In this work we studied the feasibility of detecting the depth of interaction (DOI) with two layers of crystal arrays of LYSO and BGO scintillators coupled to a position-sensitive photomultiplier tube (PS-PMT) R8900-C12. A front-end electronics was designed, with which we got different pulse shapes for different crystals to obtain depth information. With the double integration method, we got the DOI histogram of a divided integration ratio of two crystals as the standard to determine the layer-of-interaction. The DOI accuracy, measured by scanning a 22Na slit source along the side of the module, was 98% for the LYSO layer and 95% for the BGO layer. The energy resolution at 511keV was 13.1% for LYSO and 17.1% for BGO. We obtained good crystal separation in 2D position histograms of both layers. These results could be useful in the manufacture of PET scanners with high spatial resolutions.

关 键 词:PET DETECTOR DOI spatial resolution 

分 类 号:TL812.1[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象