Measurements of γ/γ' Lattice Misfit and γ' Volume Fraction for a Ru-containing Nickel-based Single Crystal Superalloy  被引量:3

Measurements of γ/γ' Lattice Misfit and γ' Volume Fraction for a Ru-containing Nickel-based Single Crystal Superalloy

在线阅读下载全文

作  者:X.P. Tan J.L. Liu X P Song T. Jin X.F. Sun Z.Q. Hu 

机构地区:[1]Superalloy Division, Institute of Metal Research, Chinese Academy of Sciences- Shenyang 110016, China [2]Analysis and Testing Division, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China

出  处:《Journal of Materials Science & Technology》2011年第10期899-905,共7页材料科学技术(英文版)

基  金:supported by the National Basic Research Program (973 Program) of China under grant No. 2010CB631200;the National Natural Science Foundation of China (NSFC) under grant No.50931004

摘  要:A conventional X-ray difFractometer has been used to determine the -y/y' lattice misfit and γ' volume fraction for a Ru-containing nickel-based single crystal superalloy at room temperature. The rocking curve was used to characterize the distribution of subgrains. The diffraction peaks obtained by w-20 scan were used to determine the γ/γ' lattice misfit and γ' volume fraction. A three peaks fitting model was proposed. The peak fitting results are in good agreement with the model. The X-ray diffraction results indicate that the nickel-based single crystal superalloy was not a perfect monocrystalline material, which is comprised of many subgrains; and each subgrain also consists of large numbers of mosaic structures. In addition, two anomalous reflection phenomena were found during the experiment and discussed with respect to their occurrence and impact on the measurement. The experimental results show that the γ/γ' lattice misfit and ~/r volume fraction will be various at the different regions of its dendritic microstructure. The average γ/γ' lattice misfit and γ' volume fraction of the experimental alloy are approximately-0.2% and 70%, respectively. Furthermore, the γ' volume fraction calculated by atom microprobe (AP) data is also basically consistent with the experimental results.A conventional X-ray difFractometer has been used to determine the -y/y' lattice misfit and γ' volume fraction for a Ru-containing nickel-based single crystal superalloy at room temperature. The rocking curve was used to characterize the distribution of subgrains. The diffraction peaks obtained by w-20 scan were used to determine the γ/γ' lattice misfit and γ' volume fraction. A three peaks fitting model was proposed. The peak fitting results are in good agreement with the model. The X-ray diffraction results indicate that the nickel-based single crystal superalloy was not a perfect monocrystalline material, which is comprised of many subgrains; and each subgrain also consists of large numbers of mosaic structures. In addition, two anomalous reflection phenomena were found during the experiment and discussed with respect to their occurrence and impact on the measurement. The experimental results show that the γ/γ' lattice misfit and ~/r volume fraction will be various at the different regions of its dendritic microstructure. The average γ/γ' lattice misfit and γ' volume fraction of the experimental alloy are approximately-0.2% and 70%, respectively. Furthermore, the γ' volume fraction calculated by atom microprobe (AP) data is also basically consistent with the experimental results.

关 键 词:Nickel-based superalloy MICROSTRUCTURE X-ray diffraction Lattice misfit y' volume fraction 

分 类 号:TG146.15[一般工业技术—材料科学与工程] TB333[金属学及工艺—金属材料]

 