摘  要:介绍了一种采用OPC通讯技术来实现工业计算机与S7-300实时通讯的方法。以西门子SIMATIC NET作为OPC服务器,先安装SIMATIC.NET2006版本软件,再配置PC硬件机架,设置S7-300与工业计算机的IP地址,通过创建服务器对象-创建OPC组对象-向组对象中添加多项-OPC客户端读写操作等步骤完成客户端与OPC服务器的链接,按照OPC接口规定,使用C#语言编程实现客户端程序与OPC服务器的实时通讯。A method which adopts OPC communication technology to realize real-time communication between industrial computers and S7-300 is introduced.In this method,SIMATIC NET produced by Siemens is taking as the OPC server.The implementation steps are: 1)mount the software of SIMATIC.NET2006;2)configurate a chassis for PC hardware;3)set up S7-300 and IP adress of industrial computer;4) establish OPC group objects;5) add multiterm OPC client read-write operation to fulfil the link between OPC client and OPC server.According to OPC interface rule,the real-time communication between client and OPC server is achieved by means of C# language.Abstract: A method which adopts OPC communication technology to realize real-time communication between industrial computers and $7-300 is introduced. In this method, SIMATIC NET produced by Siemens is taking as the OPC server. The implementation steps are : 1 ) mount the software of SIMATIC. NET2006 ; 2 ) eonfigu- rate a chassis for PC hardware; 3 )set up $7-300 and IP adress of industrial computer; 4) establish OPC group objects ; 5 ) add multiterm OPC client read-write operation to fulfil the link between OPC client and OPC server. According to OPC interface rule, the real-time communication between client and OPC server is achieved by means of C# language.

关 键 词:OPC通讯 服务器 客户端 

分 类 号:TP311[自动化与计算机技术—计算机软件与理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象