作 者:雷基林[1] 申立中[1] 陈志娥[1] 毕玉华[1] 陈建明
机构地区:[1]昆明理工大学云南省内燃机重点实验室,昆明650224 [2]云南新天力机械制造有限公司,昆明650300
出 处:《农业机械学报》2011年第11期19-26,共8页Transactions of the Chinese Society for Agricultural Machinery
基 金:云南省应用基础研究基金资助项目(2009ZC036M);云南省科技创新强省计划资助项目(2008AD007)
摘 要:针对卧式柴油机结构特点,设计了强制冷却闭式循环系统水套结构,在不同工况下对水套入口流量及关键点的温度和压力进行了测试与分析。利用计算流体动力学软件对冷却水套的流场、压力场和换热系数分布进行了分析,并对原水套结构进行了优化。结果表明:原水套平均流速为1.00 m/s,平均换热系数为7767 W/(m2.K),压力损失为0.027 MPa,基本符合工程设计要求;但各缸冷却水流速和传热系数不均匀,在公共水腔中部、二缸缸体水套上部出现大的漩涡,二缸鼻梁区、两个排气道下方局部区域存在流动死区。结构优化后,水套平均流速达到1.35 m/s,平均换热系数达到9 826 W/(m2.K),较原方案分别提高了35%和26.5%。在热负荷最大的缸盖鼻梁区,冷却水平均流速达到1.33 m/s,提高了41.5%,换热系数都在5 000 W/(m2.K)以上,没有出现原方案中的局部流动死区和大的漩涡。According to the structural characteristics of new-type horizontal diesel engine,the cooling jacket of forced cooling closed-loop system was designed,the temperature and pressure of inlet position and key points of cooling jacket were measured and analyzed under different working conditions.Computational fluid dynamics(CFD) software was utilized to study the fluid flow and the flow field,the pressure field and heat transfer coefficient distribution were analyzed and optimized.The results indicated that the mean flow velocity,average heat transfer coefficient and whole pressure loss of the original cooling jacket were 1.00m/s,7767W/(m2·K) and 0.027MPa respectively.They met the requirements of engineering design.But the cooling water flow velocity and average heat transfer coefficient between two cylinder bore were non-uniform.There were big swirls in the central region in public cavity and the top region in the second cylinder block water jacket and dead flow region in the bridge of the nose area of the second cylinder head and the local area below two exhaust port.After optimization,the mean flow velocity and average heat transfer coefficient came up to 1.35m/s and 9826W/(m2·K),increased by 35% and 26.5% respectively than the original design.The mean flow velocity of cooling water came up to 1.33m/s,increased by 41.5% and the average heat transfer coefficient was greater than 5000W/(m2·K) in the bridge of the nose area of cylinder head.Compared to the original design,there was no dead flow region,no big swirls existed in new cooling jacket.
分 类 号:TK422[动力工程及工程热物理—动力机械及工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7