多通道GPS定时接收机的测量数据处理方法和结果比较  被引量:1

COMPARISON OF METHODS AND IT'S RESULTS OF MEASUREMENT AND DATA PROCESSING ON A MULTICHANNEL GPS TIMING RECEIVER

在线阅读下载全文

作  者:胡锦伦[1] 

机构地区:[1]中国科学院上海天文台,上海200030

出  处:《中国科学院上海天文台年刊》2000年第0期134-139,共6页Annals Shanghai Astronomical Observatory Chinese Academy of Sciences

摘  要:用上海天文台研制的八通道GPS定时接收机PTS - 1[1] ,进行了不同的测量数据处理方法比较。采用测量平均法和测量拟合法的结果表明 ,定时精度和测频精度比单点测量法提高 2~ 3倍 ,达到 30ns和 3× 10 - 13/d。这种低代价的轻便接收机能获得更好的效益 ,对许多用户是有实用价值的。The different methods and its results of measurement-data processinghave were compared, by using the eight-channel GPS timing receiver PTS-1 [1] that developed by Shanghai Astronomical Observatory. The results adopted by the methods of measurement-averaging and measurement-fitting are showns that the precisions of timing and measuring frequency improve about 2~3 times than with the results of measurement methods of a single point, they arrive 30ns and 3×10 -13 /d respectively. The portable receiver of low cost can obtained more benefit, it is practical value for many users.

关 键 词:全球定位系统(GPS) 时间比对 时间同步 频率测量 

分 类 号:P127[天文地球—天体测量]

 