检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]Institute of Photographic Chemistry, Academia Sinica, Beijing 100101, PRC
出 处:《Science China Chemistry》1993年第10期1186-1197,共12页中国科学(化学英文版)
摘 要:A discrete model was used for studying the effects of exciton annihilation on the decay behavior of the excited state in phycobiliprotein super-molecules. The simulation shows: The more the chromophores are and the higher the excitation beam intensity is, the more susceptible to annihilation is a system; annihilation starts to occur at 10^(13) photons/cm^2 and becomes saturated at about 10^(15)—10^(16) photons/cm^2 with the parameters used in the current work. Whether the exciton annihilation occurs or not should not be simply judged from whether the decaying data could be fitted with a mono-exponential function. The quantum yield of fluorescence decreases synchronously with the increase of exciton annihilation extent. The so called 'safety intensity' has significance only in special cases. In fact, annihilation extent is dependent not only on the pulse intensity but also on the width of the pulse, the optical cross section of a chromophore as well as the light absorption coefficient of a system.A discrete model was used for studying the effects of exciton annihilation on the decay behavior of the excited state in phycobiliprotein super-molecules. The simulation shows: The more the chromophores are and the higher the excitation beam intensity is, the more susceptible to annihilation is a system; annihilation starts to occur at 10<sup>13</sup> photons/cm<sup>2</sup> and becomes saturated at about 10<sup>15</sup>—10<sup>16</sup> photons/cm<sup>2</sup> with the parameters used in the current work. Whether the exciton annihilation occurs or not should not be simply judged from whether the decaying data could be fitted with a mono-exponential function. The quantum yield of fluorescence decreases synchronously with the increase of exciton annihilation extent. The so called "safety intensity" has significance only in special cases. In fact, annihilation extent is dependent not only on the pulse intensity but also on the width of the pulse, the optical cross section of a chromophore as well as the light absorption coefficient of a system.
关 键 词:PHYCOBILIPROTEIN EXCITON ANNIHILATION MONTE Carlo computer simulation.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.70