检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]School of Electrical Engineering and Automation,Tianjin University
出 处:《Transactions of Tianjin University》2011年第6期418-423,共6页天津大学学报(英文版)
基 金:Supported by National Natural Science Foundation of China (No.60820106002,No.60532020);Natural Science Foundation of Tianjin(No.11JCYBJC06900)
摘 要:In this paper, a novel reconstruction technique based on level set method and algebraic reconstruction technique is proposed for multiphase flow computed tomography (CT) system. The curvature-driven noise reduction method is inserted into the conventional iteration procedure of algebraic reconstruction technique to improve the image quality and convergence speed with limited projection data. By evolving the image as a set of iso-intensity contours after each updation, the sufficient number of iterations for acceptable results is reduced by 80%-90%, while the image quality is enhanced obviously. Quantitative evaluation of image quality is given by using both relative image error and correlation coefficient. The resultant images can be utilized to detect flow regimes for monitoring industrial multiphase flow. Laboratory results demonstrate the feasibility of the proposed method. Phantoms of four typical flow regimes can be reconstructed from few-view projection data efficiently, and the corresponding image errors and correlation coefficients are acceptable for the cases tested in this paper.In this paper, a novel reconstruction technique based on level set method and algebraic reconstruction technique is proposed for multiphase flow computed tomography (CT) system. The curvature-driven noise reduction method is inserted into the conventional iteration procedure of algebraic reconstruction technique to improve the image quality and convergence speed with limited projection data. By evolving the image as a set of iso-intensity contours after each updation, the sufficient number of iterations for acceptable results is reduced by 80%--90%, while the image quality is enhanced obviously. Quantitative evaluation of image quality is given by using both relative image error and correlation coefficient. The resultant images can be utilized to detect flow regimes for monitoring industrial multiphase flow. Laboratory results demonstrate the feasibility of the proposed method. Phantoms of four typical flow regimes can be reconstructed from few-view projection data efficiently, and the corresponding image errors and correlation coefficients are acceptable for the cases tested in this paper.
关 键 词:computed tomography multiphase flow image reconstruction
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.217.108.153