检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:D. Guo D. Lathi H. Griffiths N. Harid A. Ainsley A. Haddad
机构地区:[1]National Grid, Warwick, UK [2]High Voltage Energy Systems Group, Cardiff University, Cardiff, UK
出 处:《高电压技术》2011年第11期2733-2738,共6页High Voltage Engineering
基 金:National Grid for supporting this research work
摘 要:Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/ impedance and to estimate the potential distribution in the vicinity of earth electrodes.However,very little literature is available on experimental validation of these calculation techniques.To address this,a programme of experimental tests on various earth electrodes has been carried out at the lower water reservoir of a hydro pumped-storage power station in North Wales.In this paper,the earthing test facility at Dinorwig power station is described including the details of the experimental set up.The results from experimental tests on a 5 mX5 m earth grid,immersed in water and energized under ac,dc and impulse,are presented.The values of measured earth resistance/impedance and water surface potential distributions are compared with those obtained from analytical calculations and detailed numerical computer simulations.Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/ impedance and to estimate the potential distribution in the vicinity of earth electrodes. However, very little literature is available on experimental validation of these calculation techniques. To address this, a programme of experimental tests on various earth electrodes has been carried out at the lower water reservoir of a hydro pumped-storage power station in North Wales. In this paper, the earthing test facility at Dinorwig power station is described including the details of the experimental set up. The results from experimental tests on a 5 m× 5 m earth grid, immersed in water and energized under ac, dc and impulse, are presented. The values of measured earth resistance/impedance and water surface potential distributions are compared with those obtained from analytical calculations and detailed numerical computer simulations.
关 键 词:earthing systems earth impedance RESISTIVITY surface potential distribution
分 类 号:TM862[电气工程—高电压与绝缘技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.14.12.254