某市高层办公楼建筑水耗及超压出流实测分析  被引量:2

Measurement and Analysis of Water Consumption and Overpressure Outflow in High-rise Office Buildings in a City

在线阅读下载全文

作  者:李稳[1] 张希伊 董良飞[1] 张凤娥[1] 赵玲萍[1] 

机构地区:[1]常州大学环境与安全工程学院,江苏常州213164 [2]太仓市水利局城厢水利站,江苏苏州215400

出  处:《中国给水排水》2011年第23期56-59,共4页China Water & Wastewater

摘  要:进行了某市5幢典型高层办公楼的水耗调查和超压出流测试分析,总结了超压出流原因。调查结果表明,绝大多数办公楼的纯办公人员用水单耗超出国家定额;在所有41个测点中,水压超过0.45 MPa的测点有10个,达到24.4%;快开水龙头在半开状态下超压出流率达67%,而在全开状态下超压出流率高达98%;单把陶瓷水龙头(节水水龙头)在测试中的超压出流率为20%。The water consumption and overpressure outflow in five typical high-rise office buildings in a city were measured and analyzed. The reasons for overpressure outflow were summarized. The survey results show that the water consumption per unit for pure office staff in the vast majority of office buildings exceeds the national norm. There are 10 measuring points over 0.45 MPa in all 41 measuring points, reaching 24.4%. When the fast on faucet is in half-open position, the overpressure outflow rate reaches 67% , while in the fully open position, the overpressure outflow rate is as high as 98%. The overpressure outflow rate of the single ceramic faucet (water saving faucet) is 20%.

关 键 词:建筑用水调查 超压出流 水耗分析 

分 类 号:TU991.64[建筑科学—市政工程]

 