120t/d液化装置带水故障分析与处理  

Analysis and treatment of water-carrying trouble of 120 t/d liquefying equipment

在线阅读下载全文

作  者:李宗辉[1] 赵云河[1] 刘玉良[1] 

机构地区:[1]济南鲍德气体有限公司,山东省济南市工业北路21号250101

出  处:《深冷技术》2011年第6期51-53,共3页

摘  要:由于新建4#30000 m3/h中压氮压机投运前未进行管网供需平衡分析,造成了120 t/d液化装置带水故障。简介鲍德气体中、低压氮气生产供应现状,从液化装置本身、中压氮压机以及相应管网等方面,分析了120 t/d液化装置带水的原因,阐述了相应的处理措施和预防措施。The water-carrying trouble occurred in 120 t/d liquefying equipment, since before commissioning of 4 # new-built 30000 m3/h medium pressure nitrogen compressor the supply-demand balance of pipeline net was not analyzed. The production and supply state of medium-and low-pressure gaseous nitrogen of Baode Gas Co., Ltd, is briefed. The causes for the said trouble are analyzed from the liquefying equipment proper, the medium pressure nitrogen compressor and corresponding pipeline net, and the corresponding corrective and preventive measures are described.

关 键 词:液化装置 带水 堵塞 氮压机 处理 

分 类 号:TQ116.11[化学工程—无机化工]

 