消毒供应室蒸汽灭菌后产生湿包的原因及对策  被引量:2

The causes of wet pack after sterile supply room steam sterilization and countermeasures

在线阅读下载全文

作  者:牛芹[1] 

机构地区:[1]徐州医学院附属连云港市第一人民医院消毒供应室,江苏连云港222002

出  处:《中国民康医学》2011年第22期2809-2809,2829,共2页Medical Journal of Chinese People’s Health

摘  要:目的:探讨蒸汽灭菌后湿包产生的原因,避免灭菌后物品造成二次污染,确保无菌物品的质量和使用安全。方法:查找形成湿包的原因,并积极采取有效的对策加以控制。结果:湿包形成的原因主要是物品包装及装载不规范、干燥及冷却方法不当、物品或器械在包装前呈潮湿状态等。结论:消毒供应室工作人员通过严格规范操作、加强管理,湿包现象明显减少。Objective:To investigate the causes of wet pack after steam sterilization,to avoid items secondary pollution,to ensure the quality and use safety.Methods:Find the reasons for the formation of the wet pack,and take effective countermeasures to control.Results:The main reason for the formation of the wet pack is packed and loaded non-standard items,improper drying and cooling methods,materials or equipment before packing was wet state and other factors.Conclusion:The sterile supply room staff through rigorous standards,strengthen management,significantly reduced the phenomenon of the wet pack.

关 键 词:消毒供应室 蒸汽灭菌 湿包 

分 类 号:R472.1[医药卫生—护理学]

 