摘  要:某台600 MW汽轮发电机组在大修后带负荷运行中,3X和5X轴的振动较大,4号瓦和6号瓦的瓦振较大;在降速过程中4号瓦、5号瓦和6号瓦出现不同程度的二倍频分量。结合机组检修过程及动平衡过程对上述振动现象进行了分析,指出质量不平衡、轴承紧力不足以及联轴器平行不对中是引起上述振动的原因,并通过动平衡方法以及增加轴承紧力,使得振动故障得以解决。Vibration failure occurred to one 600 MW steam turbine after the scheduled maintenance.Large vibration was discovered at 3X and 5X during operation duration,while 2 times frequency components were found during deceleration process at No.4,5 and 6 tiles.According to the maintenance and dynamic process,the mentioned issues are analyzed in the paper,and mass unbalance,insufficient force on bearing and misalignment of coupling are believed to be the main reasons.This problem has been successfully solved through dynamic balance method and enhancing bearing force.