检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海理工大学电气工程学院,上海200093 [2]许继集团,河南许昌461000
出 处:《电力自动化设备》2011年第12期54-58,共5页Electric Power Automation Equipment
摘 要:在并网逆变器中引入LCL滤波器取代单个电感滤波器。并针对采用LCL滤波器对并网逆变器系统带来的不稳定性,分别对比了以并网电流作为反馈变量和逆变器侧电流作为反馈变量的电流内环控制方法,提出了基于桥臂输出电流闭环与电压外环的双环控制策略。由于以并网电流为反馈变量的控制系统为三阶系统,所提控制系统稳定性和鲁棒性较好。搭建了三相光伏并网逆变系统,实现了最大功率点跟踪,高功率因数并网,结果验证了理论分析的正确性以及控制策略的可行性。LCL filter is introduced to replace the individual inductance filter of grid-connected inverter. Based on the comparison between grid-side current and inverter-side current taken as its feedback variable of the inner current loop control,a dual close-loop control of inner bridge current loop and outer voltage loop is proposed to remove the instability caused by the inverter system with LCL filter. The control loop with the grid current as its feedback variable is a three-order system,which has good system stability and robustness. A three-phase inverter system for photovoltaic grid connection is established and the performance of MPPT(Maximum Power Point Tracking) and high power factor are realized. The correctness of theoretical analysis and the feasibility of the proposed control strategy are both proved by simulative and exnerimental results.