Flow-injection Spectrophotometric Determination of Uric Acid in Urine via Prussian Blue Reaction  被引量:1

Flow-injection Spectrophotometric Determination of Uric Acid in Urine via Prussian Blue Reaction

在线阅读下载全文

作  者:WASEEM Amir YAQOOB Mohammad NABI Abdul MURTAZA Ghulam HUSSAIN Izhar 

机构地区:[1]Department of Chemistry, COMSATS Institute of Information Technology [2]Department of Chemistry, University of Balochistan [3]Department of Pharmacy, COMSATS Institute of Information Technology

出  处:《Chemical Research in Chinese Universities》2011年第6期929-933,共5页高等学校化学研究(英文版)

基  金:Supported by the CIIT-Project Funded by COMSATS Institute of Information Technology,Pakistan

摘  要:A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ions reacted with unreduced portion of ferricyanide/Fe(III) to form soluble Prussian blue, which was monitored at an absorption wavelength of 735 nm. The optimized conditions allow a linear calibration graph in a concentration range of 1―100 μmol/L. The relative standard deviation was in a range of 0.5%―2.5%, with a detection limit(3σ blank) of 0.3 μmol/L and a sampling frequency of 60 injection/h was obtained. The effect of common substances present in human physiological fluids on the determination of uric acid was examined. The method was applied to determining uric acid in human urine samples with the recoveries in a range of 96%―105%. The results agree well with those by spectrophotometric reference method at a confidence level of 95%. Spectrophotometric procedures for uric acid determination in clinical samples were reviewed briefly.A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ions reacted with unreduced portion of ferricyanide/Fe(III) to form soluble Prussian blue, which was monitored at an absorption wavelength of 735 nm. The optimized conditions allow a linear calibration graph in a concentration range of 1―100 μmol/L. The relative standard deviation was in a range of 0.5%―2.5%, with a detection limit(3σ blank) of 0.3 μmol/L and a sampling frequency of 60 injection/h was obtained. The effect of common substances present in human physiological fluids on the determination of uric acid was examined. The method was applied to determining uric acid in human urine samples with the recoveries in a range of 96%―105%. The results agree well with those by spectrophotometric reference method at a confidence level of 95%. Spectrophotometric procedures for uric acid determination in clinical samples were reviewed briefly.

关 键 词:Flow injection analysis SPECTROPHOTOMETRY Uric acid Prussian blue URINE 

分 类 号:R446.1[医药卫生—诊断学] O657.3[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象