检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《环境科学导刊》2012年第1期101-103,共3页Environmental Science Survey
基 金:水专项<地表水环境质量特定监测项目分析测试方法优化研究>(2009ZX07527-001)
摘 要:对氨氮真空玻璃检测管法和纳氏试剂光度法进行检出限、精密度、准确度,以及实际样品测试方面的比较研究。研究表明,氨氮检测管的检出限为0.2mg/L,精密度测定的相对标准偏差为0%~5.75%,准确度测定的加标回收率为93%~124%。检测管法和纳氏剂法同时测定多种实际样品,结果两种方法的相对误差为-37.8%~11.8%,结论:检测管法能够满足半定量测试的需求。The comparative study was conducted on vacuum glass detection tube methods and the Nessler' s reagent spectrophotometry in respect of detection limit, precision, accuracy and sample testing. It shows that the detection limit of ammonia nitrogen by detection tube is 0. 2mg/L, the relative standard deviation of precision is 0% -5. 75% , and the recovery of standard addition of accuracy is 93% -124%. When testing various actual samples by the two methods, we have found that the relative deviation of both methods is -37. 8% -11. 8%. It is concluded that detection tube method could meet the needs of semi - quantitative test.
分 类 号:X83[环境科学与工程—环境工程]