数字化X线胸部摄影参数优化的探讨  被引量:6

The study of optimization in chest digital radiography

在线阅读下载全文

作  者:郭良栋[1] 娄从辉 孙进城 黄茹[1] 吴强[1] 

机构地区:[1]邳州市人民医院放射科,江苏邳州221300

出  处:《实用放射学杂志》2011年第12期1908-1910,共3页Journal of Practical Radiology

摘  要:目的 探讨数字化X线胸部摄影参数的优化,以确保影像质量和降低X线曝光量.方法 用碘化色-非晶硅平板探测器数字化X线摄影系统对30例患者(志愿者)用90 kV和125 kV行胸部后前站立位数字化X线摄影,评价影像质量和X线曝光量的大小.结果 胸部125 kV数字化X线摄影比90 kV数字化X线摄影可减少X线曝光量约68%,影像层次更丰富.结论 数字化X线胸部摄影应以高千伏(125 kV)摄影为宜.Objective To study of optimization in chest digital radiography(DR), in order to ensure image quality and reduce amount of X-ray exposure. Methods 30 cases underwe,at chest DR examinations with cesium iodide anlorphous silicon flat panel de rector of the digital X ray system using 90 kV and 125 kV. The image qu+dity and the dose of X ray exposure were evaluated. Results The radiation dose at chest DR using 125 kV could he reduced aboul 68% compared with that using 90 kV, and the image quality was fine. Conclusion Digital X ray high kV(125kV) chest radiography should he suitable photography.

关 键 词:放射摄影术 胸部 质量控制 

分 类 号:R814[医药卫生—影像医学与核医学] R816.4[医药卫生—放射医学]

 