检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李卫虹[1] 李昭屏[1] 张会欣 胡艳丽[3] 肖文华[4] 王琛[4]
机构地区:[1]北京大学第三医院心内科卫生部心血管分子生物学与调节肽重点实验室,北京市100191 [2]石家庄市二院功能科 [3]中国人民武装警察部队北京市总队第二医院心内科 [4]北京大学第三医院内分泌科,北京市100191
出 处:《中国循环杂志》2011年第6期446-449,共4页Chinese Circulation Journal
摘 要:目的:运用左心室壁中层缩短率评价2型糖尿病患者早期左心室收缩功能改变。方法:51例2型糖尿病者(糖尿病组)及30例体验正常者(对照组),行常规及组织多普勒超声心动图检查,测量左心室壁中层缩短率(mFS),计算左心室经线及圆周收缩末期应力,对两组间左心室结构和收缩功能指标即mFS、左心室射血分数、左心室短轴缩短率(LVFS)和二尖瓣环收缩期峰值运动速度(Sm)进行比较,并对mFS与左心室结构参数、空腹血糖水平行相关分析。结果:糖尿病组与对照组比较,左心室舒张末径、左心室收缩末径、左心室质量、左心室心肌质量指数均增加(P<0.01),mFS减低[(21.9±3.4)%vs(24.2±2.6)%,P<0.01]。两组间舒张期室间隔厚度、舒张期左心室后壁厚度及相对室壁厚度比较,差异无统计学意义。mFS与左心室收缩末径、左心室质量、左心室心肌质量指数负相关(r值分别为-0.586、-0.332和-0.239,P<0.05),与空腹血糖水平亦呈负相关(r=-0.315,P=0.011),这种负相关在校正了年龄、性别、收缩压和体重指数的影响后仍然存在。结论:2型糖尿病患者存在亚临床的左心室收缩功能变化,室壁中层缩短率是检测糖尿病患者早期心肌收缩力下降的敏感指标。Objective: To assess the early changes of left ventricular systolic function by ventricular midwall fractional shortening (mFS) in patients with type 2 diabetes mellitus (DM). Methods: Our study included two groups, DM group, n = 51 and Control group, n=30 volunteers without DM. Echocardio- graphy was performed in all participants to detect mFS, to calculate left ventricular circumferential end-systohc stress and to com- pare left ventricular ejection fraction (LVEF), left ventricular fractional shortening (LVFS), and mitral annular systolic velocity (Sin) between two groups. In addition, the correlations between mFS and the parameters of cardiac structure and fasting blood glu- cose (FBG) level were analyzed. Results: Compared with Control group, DM group had increased diameter of left ventricle, increased left ventricular mass (LVM) and left ventricular mass index (LVMI),P〈0. 01 respectively. DM group had lower mFS than that in Control group(21.9 ±3.4) % vs. (24. 2±2. 6)% ,P〈0. 01. There was no statistic difference for the relative thickness of ventricular wall between two groups, mFS was negatively correlated to left ventricular end-systolic diameter, LVM and LVMI(r=-0. 586, r=-0. 332 and r = -0. 239,P〈0. 05 respectively), mFS was negatively related to FBG ( r = -0. 315,P= 0.011 ). With the adjusted influence of age, gender, systolic blood pressure and body mass index, those negative correlations were still exist. Conclusion: Type 2 DM patients have sub-clinical left ventricular systolic functional changes, mFS is a sensitive parameter for assessing the early ventricular systolic dysfunction in DM patients.
关 键 词:糖尿病 超声心动图 左心室收缩功能 左心室壁中层缩短率
分 类 号:R541[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.15.10.218