脑电信号中眼电伪迹的自动去除算法  被引量:7

Automatic Removal Algorithm of Ocular Artifact in Electroencephalogram Signal

在线阅读下载全文

作  者:王魁[1] 叶闯[1] 沈益青[1] 王柏祥[1] 

机构地区:[1]浙江大学信息与电子工程学系电子电路与信息系统研究所,杭州310027

出  处:《计算机工程》2011年第23期257-260,共4页Computer Engineering

基  金:国家自然科学基金资助项目(60503027)

摘  要:为实现眼电伪迹的自动去除,提高算法的有效性和稳健性,提出一种眼电伪迹自动去除算法。采用样本熵和一种通用的伪迹判决方法对眼电伪迹进行自动识别,通过脑电信号的重构实现眼电伪迹的去除。实验结果表明,对于不同长度的真实脑电信号,该算法均能准确地去除眼电伪迹,较好地保留其他的脑电信号成分,且可以完全自动地去除眼电伪迹,适用于实时场合。In order to automatically remove the ocular artifact from Electroencephalogram(EEG) data,this paper presents an effective and robust algorithm.Blind Source Separation(BSS) algorithm is used to separate real EEG signal,and a universal approach together with sample entropy is employed to identify the artifact components.The artifact is eliminated through reconstruction of EEG data.Simulation results are compared with a robust method based on fractal dimension and show the proposed algorithm can eliminate ocular artifact accurately and do little harm to useful EEG signals that for real EEG data of different lengths.Meanwhile,the proposed method does not need any reference channel,and is fully automated,which is suitable for real-time applications.

关 键 词:脑电信号 二阶盲辨识 眼电伪迹 样本熵 分形维数 

分 类 号:TN911.72[电子电信—通信与信息系统]

 