卷式反渗透膜的气液两相流清洗特性  被引量:3

Cleaning properties of spiral reverse osmosis membrane with gas-liquid two-phase flow process

在线阅读下载全文

作  者:郭竹洁[1] 王枢[1] 孟涛[1] 王娇[1] 

机构地区:[1]西南交通大学生命科学与工程学院,成都610031

出  处:《膜科学与技术》2011年第6期73-77,共5页Membrane Science and Technology

基  金:国家自然科学基金资助项目(20706046)

摘  要:建立新型膜清洗装置,将压缩空气和化学清洗液形成气液两相混合流体对2.5英寸(1英寸-25.4mm)卷式反渗透膜进行清洗研究.系统地探讨了气液两相流清洗过程中清洗液流量、气体流速、气液比、清洗时间对膜截留率和通量恢复率的影响.结果表明清洗液在0.12L/min时,即可获得较好的膜通量恢复率.不同过滤面积的反渗透膜,清洗液的临界流量不同,超过该流量对膜通量恢复率无明显影响.膜通量恢复率随气体流速的增加而增加,聚酰胺材质反渗透膜气速上限是18m/s,更高的气速将降低膜截留率.气液比在2000:1~3000:1范围内能有效提高膜通量恢复率.两相流清洗时间一般不超过15min就能获得理想清洗效果.A novel membrane cleaning apparatus was constructed and used to study the cleaning of 2. 5-inch spiral RO membrane with gas-liquid two-phase flow process. The two-phase flow mixture was formed by cleaning liquid mixed with compressed air. The effects of cleaning liquid flow rate, air velocity, gas to liquid ratio and cleaning time of gas-liquid two-phase flow process on rejection rate and flux recovery ratio (FRR) of RO membrane were investigated systematically. The results show that high FRR is achieved by relatively low cleaning liquid flow rate about 0. 12 L/rain. RO membranes with different active areas have different cleaning critical flow rates. Above the critical flow rate, ERR increases slowly. FRR increases with increasing air velocity. For polyamide composite RO membrane, the upper limit of air velocity is 18 m/s and higher air velocity would decrease rejection rate of membrane. FRR is effectively improved when the gas to liquid ratio is from 2 000 : 1 to 3 000 : 1. The two-phase flow process is validated for cleaning 2.5-inch RO membranes effectively using a short 15-minute cycle.

关 键 词:气液两相流 膜清洗 卷式反渗透膜 截留率 通量恢复率 气体流速 气液比 

分 类 号:TQ028.8[化学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象