高钛冷固球中二氧化钛的测定与改进  

Determination and Improvement of the Titanium Dioxide in Cold-bounded High-titanium Ball

在线阅读下载全文

作  者:卢和平 郭宜鑫 尚玉民[3] 

机构地区:[1]济南济钢铁合金厂,山东济南250105 [2]山东球墨铸铁管有限公司,山东济南250101 [3]济南钢铁股份有限公司炼钢厂,山东济南250101

出  处:《山东冶金》2011年第6期41-42,46,共3页Shandong Metallurgy

摘  要:熔融物用热水浸取后,经过滤分离去除了干扰元素钒,从而改进了测定高钛冷固球中二氧化钛的标准方法,实验并确定了测定过程中的最佳分析条件。应用该法分析高钛冷固球中的二氧化钛含量,其相对标准偏差<0.4%,结果与标准方法相比误差更小。The melt was leached with hot water, the interference element of V was removed after filtration and separation, the standard method for determining of titanium dioxide content in cold-bounded high-titanium ball was improved, and the optimal analytical conditions were tested and obtained. This method was applied to determine titamium dioxide in cold-bounded high-titanium Ball, and the relative standard deviation (RSD) was smaller than 0.4%. Compared with the standard method, this method error was less.

关 键 词:高钛冷固球 二氧化钛  干扰元素 

分 类 号:O655.2[理学—分析化学]

 