降解氯苯废气生物滴滤塔挂膜启动方式  被引量:3

Study on the Start-up and Biofilm Culturing in Biotrickling Filter Treating Waste Gas Containing Chlorobenzene

在线阅读下载全文

作  者:杨百忍[1] 丁成[1] 

机构地区:[1]盐城工学院环境科学与工程学院,江苏盐城224051

出  处:《盐城工学院学报(自然科学版)》2011年第4期60-63,共4页Journal of Yancheng Institute of Technology:Natural Science Edition

基  金:科技部科技型中小企业技术创新基金项目(09C26213203714);盐城工学院校级科研项目(XKY2011024)

摘  要:以装填活性炭纤维布填料的生物滴滤塔为试验装置,以模拟氯苯废气为降解目标物,分别采用快速排泥法和气液相联合法对滴滤塔进行挂膜启动。结果表明:气液相联合法23 d实现挂膜启动,比快速排泥法挂膜启动时间缩短20 d左右,去除率变化更加稳定,进气中氯苯浓度4 000 mg/m3时两者去除率均达到50%。The start-up and biofilm culturing process of biotrickling filters treating waste gas containing chlorobenzene were studied.Sludge fast discharge method and gas-liquid phase joint inoculation method were used during start-up.The results showed that the start-up time of the latter is shorter,i.e.about 20 d,the removal efficiency kept above 50% when inlet chlorobenzene concentration about 4 000 mg/m3 at the end of start-up.

关 键 词:生物滴滤塔 挂膜 启动 氯苯废气 

分 类 号:TQ177.2[化学工程—硅酸盐工业]

 