作 者:郑力军[1,2] 张涛[1,2] 王兴宏[1,2] 马丽萍[1,2] 张伟[3]
机构地区:[1]中国石油长庆油田分公司油气工艺研究院 [2]陕西西安"低渗透油气田勘探开发国家工程实验室" [3]中国石油长庆油田分公司第三采油厂
出 处:《石油与天然气化工》2011年第6期607-609,540,共3页Chemical engineering of oil & gas
摘 要:针对靖安油田地层条件,对起泡剂的起泡能力和稳定性等进行分析,筛选出界面张力达到10-1 mN/m的低界面张力泡沫体系。性能评价表明,该体系具有较好的起泡性、稳泡性和较强的耐温抗盐性。运用单管驱油实验对泡沫体系阻力因子进行了评价,确定最佳气液比为2∶1;双管驱油实验表明,泡沫可以实现对高低渗填砂管的均匀分流,水驱后再注入此泡沫体系,综合采收率可以提高10.94%。In view of reservoir conditions in Jingan oil field,a low interfacial tension's foaming system with interfacial tension of 10-1mN/m was screened out by analyzing the foaming ability and stability of several foaming agents.The result of the performance evaluation shows that the system has good foam performance,good heat resistance and salt tolerance.The resisting force factor of the foaming system is evaluated through singlet-tube flooding experiment,then the optimal gas fluid ratio is determined to be 2∶1.The double-tube flooding experiment result shows that foaming system can be distributed uniformly between high and low transmissibility tube,and the comprehensive recovery is enhanced 10.94% by injecting the foam system after water flooding.
分 类 号:TE357.4[石油与天然气工程—油气田开发工程]