作 者:辛玉新[1,2,3] 屈中权[1,3] 范玉峰[1,3] 张瑞龙[1,3] 和寿圣[1,3]
机构地区:[1]中国科学院云南天文台,云南昆明650011 [2]中国科学院研究生院,北京100049 [3]中国科学院天体结构与演化重点实验室,云南昆明650011
出 处:《天文研究与技术》2012年第1期78-85,共8页Astronomical Research & Technology
基 金:国家自然科学基金(11078005;10943002);科技部973项目(G2011CB811400)资助
摘 要:偏振测量是天文四大测量(光谱,光度,偏振,图像)手段之一,而检偏器是进行天体偏振测量的有力工具之一。通过TCP/IP协议控制步进电机驱动检偏器旋转一定的角度值,通过RS485串行通讯实时读取光电绝对编码器的读数作为检偏器绝对位置的反馈量,从而构成一个闭环控制系统。最终实现了转动误差0.42°,步进角度22.5°,转动范围0°~360°的偏振闭环控制系统,完全满足天体偏振测量的基本要求。Polarimetry is one of the four major types of astronomical measurements ( spectroscopy, photometry, polarimetry, and imaging). A polarization analyzer is an effective tool in polarimetry. We have realized a closed-loop polarization-analyzer control system, which consists of a step motor and an absolute encoder. The step motor is controlled through the TCP/IP protocol, and the encoder is controlled through the RS485 serial communication. The system has a polarization-angle measurement error of 0.42°, a stepping angle of 22.5°, and a slew range of 0 - 360°. These sufficiently meet the requirements for polarimetry. A traditional polarization-analyzer control system is of open loop and contains a step motor and a Hall device. Through the Hall-effect switch the initial position of the polarizer can be determined, and then commands are sent to the step motor for designated angles, such as 45°, 90°, 135°, and 180°. It is easy to be operated to realize its basic function but it has large errors because of lost steps of the motor, the number of which is hardly known. In case when the system is restarted after unexpected power out, the current position of the motor cannot be specified and the entire system (including the step motor) has to be initiated again. We use an absolute encoder to replace the Hall device in our closed-loop polarization-analyzer control system. We can inquire the absolute encoder to retrieve the information about the current position of the polarizer. The systematic error can be controlled by the encoder also, and the positioning accuracy depends on the resolution power of the encoder. There is no need to worry about any power off for the system because the position is displayed in real time. Overall, our polarization-analyzer control system has very good positioning accuracy and robust performance. It is convenient for polarimetric applications.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28