1177t/h循环流化床锅炉燃烧优化调整试验及结果分析  被引量:10

DEBUGGING TEST OF COMBUSTION OPTIMIZATION AND RESULT ANALYSIS FOR ONE 1177t/h CFB BOILER

在线阅读下载全文

作  者:杨勇 刘海峰[2] 王海涛[2] 王鹏利[2] 高洪培[2] 肖平[2] 

机构地区:[1]陕西新元洁能有限公司,陕西府谷719404 [2]华能清洁能源技术研究院,北京100098

出  处:《热力发电》2012年第1期53-55,共3页Thermal Power Generation

摘  要:对1 177t/h循环流化床(CFB)锅炉进行的燃烧优化调整试验结果表明,经燃烧优化调整,锅炉热效率平均为92.232%,比调整前提高约1.5%~2.0%,每年可节约燃料成本约840万元;稀相区烟气速度由调整前的4.22m/s降至3.87m/s,可减少磨损量约25%。The debugging test of combustion optimization on one 1 177 t/h CFB boiler has been carried out. Results show that the thermal efficiency of said boiler after combustion optimization and adjustment has enhanced about 1.5-2% ,the flue gas velocity in dilute -phase zone has decreased from 4. 22 m/s before adjustment to 3.87 m/s,the abrasion has reduced about 25% ,the electric current of the primary air fan,the secondary air fan,and the induced draft fan has decreased from about 1 350 A before test to 1 240-1 280 A,reducing about 70-110 A.

关 键 词:CFB锅炉 燃烧优化 热效率 磨损 调整试验 

分 类 号:TK229[动力工程及工程热物理—动力机械及工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象