综合改进控制方法消除压力蒸汽灭菌后湿包现象的研究  被引量:2

Appling upgraded control method to eliminate hygro-package in steam sterilization

在线阅读下载全文

作  者:牛璐[1] 邹秀珍[1] 

机构地区:[1]江苏省连云港市第一人民医院,江苏连云港222002

出  处:《中国民康医学》2012年第2期148-149,222,共3页Medical Journal of Chinese People’s Health

摘  要:目的:研究消除压力蒸汽灭菌湿包现象的有效方法。方法:2010年1~12月,按照原方法与改进方法分为两组进行压力蒸汽灭菌消毒,统计湿包数。结果:改进控制方法后湿包数量明显减少,差异有统计学意义。结论:根据导致压力蒸汽灭菌后出现湿包的常见原因,采取有效改进措施,可以明显减少湿包现象的发生,避免二次污染,保证灭菌质量。Objective: Appling upgraded control method to eliminate hygro - package in steam sterilization. Methods: From January to December 2010 in our hospital supplies,all steam sterilization were divided into two groups according to different methods. Results: Hygro - package in steam sterilization was significantly reduced after appling upgrade control method ( P 〈 0.05 ). Conclusion: Appling upgrade control method can significantly reduced hygro - package in steam sterilization according to reasons of it, avoid secondary pollution and guarantee sterilization quantity.

关 键 词:医院供应室 改进控制方法 蒸汽灭菌 湿包 

分 类 号:R197.39[医药卫生—卫生事业管理]

 