检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张超 陈楠[2] 王星[2] 卓彦[3] 陈霖[3] 李坤成[2]
机构地区:[1]中国核工业北京401医院放射科,北京102413 [2]首都医科大学宣武医院放射科,北京100053 [3]中国科学院生物物理研究所脑与认知科学国家重点实验室,北京100101
出 处:《中国医学影像技术》2012年第1期1-5,共5页Chinese Journal of Medical Imaging Technology
基 金:国家高技术研究发展计划(863计划)项目(2006AA02z391);科技部基金项目(2005CB522800;2004CB318101);国家自然科学基金(30621004;30870697)
摘 要:目的比较扣带回体积与校正因素的关系,为扣带回结构提供标准化的测量方法。方法对627名18~60岁中国正常成年志愿者行全脑MR容积扫描,应用3D体积分析软件手工勾绘ROI,测量扣带回的体积,并分别以颅内容积(TIV)和脑体积(WBV)进行校正。对校正前、后的扣带回体积分别与TIV和WBV进行相关性分析。结果校正前和TIV、WBV校正后的扣带回体积:男性分别为(21.01±2.31)ml、(21.11±2.57)ml(、21.06±2.34)ml,女性分别为(19.72±2.31)ml(、19.79±2.28)ml(、19.74±2.04)ml;左侧分别为(9.71±1.54)ml(、9.77±1.61)ml、(9.75±1.54)ml,右侧分别为(10.64±1.58)ml、(10.69±1.53)ml、(10.67±1.45)ml。校正前的扣带回体积与TIV的相关性不强(男、女:r=0.225、0.385;左、右侧:r=0.229、0.366;P均〈0.05),与WBV的相关性略高(男、女:r=0.329、0.473;左、右侧:r=0.381、0.419;P均〈0.05);校正后的扣带回体积与TIV仍有相关性(男、女:r=-0.378、-0.379;左、右侧:r=-0.368、-0.300;P均〈0.05),与WBV相关性降低(男、女:r=-0.297、-0.156;左、右侧:r=-0.285、-0.197;P均〈0.05)。结论扣带回体积与TIV和WBV均有一定相关性;WBV校正效果优于TIV。Objective To assess the correlations of cingulate gyrus volume with corrected factor,in order to provide standard volumetric method for cingulate gyrus.Methods Totally 627 Chinese healthy volunteers(aged from 18 to 60) underwent brain three-dimensional MR scan.Cingulate gyrus volumes were manually measured with ROI using 3D volume analysis software,and were corrected by total intracranial volume(TIV) and whole brain volume(WBV),respectively.Correlation of uncorrected and corrected cingulate gyrusvolumes with TIV and WBV were analyzed,respectively.Results Uncorrected and corrected cingulate gyrus volume by TIV and WBV was(21.01±2.31)ml,(21.11±2.57)ml,(21.06±2.34)ml respectively for male,(19.72±2.31)ml,(19.79±2.28)ml,(19.74±2.04)ml respectively for female,(9.71±1.54)ml,(9.77±1.61)ml,(9.75±1.54)ml respectively for left side,(10.64±1.58)ml,(10.69±1.53)ml,(10.67±1.45)ml respectively for right side.Uncorrected cingulate gyrus volumes had lower correlation with TIV(male,female: r=0.225,0.385;left,right: r=0.229,0.366;all P0.05),and higher correlation with WBV(male,female: r=0.329,0.473;left,right: r=0.381,0.419;all P0.05).Corrected cingulate gyrus volumes were correlated with TIV(male,female: r=-0.378,-0.379;left,right: r=-0.368,-0.300;all P0.05),and had lower correlation with WBV(male,female: r=-0.297,-0.156;left,right: r=-0.285,-0.197;all P0.05).Conclusion There is correlation between cingulate gyrus volume and TIV or WBV.Cingulate gyrus volume corrected with WBV is better.
分 类 号:R445.2[医药卫生—影像医学与核医学] R32[医药卫生—诊断学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.21