作 者:陈圆[1] 郁鸿凌[1] 管晨希[1] 肖博钧[1] 杨东伟[1]
机构地区:[1]上海理工大学能源与动力工程学院,上海200093
出 处:《能源研究与信息》2011年第4期216-220,215,共6页Energy Research and Information
摘 要:高炉鼓风机作为鼓风机站重要的动力设备,同时也是耗能最大的设备,其耗电量占到鼓风机站总耗电量的97%以上,而送风管路阻力损失大小直接影响鼓风机的耗电量。以流体力学基本原理为基础,建立了高炉鼓风机机前管路阻损的数学模型。对鼓风机机前送风管路的阻力损失进行了理论解析,并与送风管路的实际运行阻力损失进行对比分析。这一模型的建立不仅给高炉鼓风系统设计计算提供有效的参考,而且对企业确保高炉鼓风机高效运行提供一定的理论支持。A blower of the blast-furnace is the most important power equipment in the blower station and its power consumption is the largest one of all equipment.Its power consumption accounts for more than 97%of the total power consumption in the blower station,and the resistance loss of pipeline directly influences the blower power consumption.Based on the fluid dynamics,a mathematical model for calculating the pipeline resistance loss upstream of the blast-furnace blower is established.The pipeline resistance losses were analyzed theoretically,and the theoretical results were analyzed and compared with the resistance losses of the blowing system in practical operation. The mathematical model provides not only an effective reference for designing the blast-furnace blowing system,but also theoretical support for the enterprise blast-furnace blower efficient operation.
分 类 号:TF321.8[冶金工程—冶金机械及自动化]