作 者:蒋鸿城[1] 戚伟强[1] 裘炜浩[1] 洪建光[1]
机构地区:[1]浙江省电力公司信息技术中心,浙江杭州310007
出 处:《电力信息化》2011年第11期16-20,共5页Electric Power Information Technology
摘 要:为提高企业信息系统抵御风险的能力,避免重要数据丢失的风险,浙江省电力公司迫切需要建设一个安全可靠的数据容灾中心。文章深入分析、探讨比较目前的容灾关键技术,同时结合浙江省电力公司营销业务应用系统的现状,最后基于远程镜像技术,成功地建设完成了营销业务应用的容灾系统,实现了零数据丢失、零时间延迟的数据容灾体系,促进浙江省电力公司整个数据容灾系统的下一步建设工作。To improve the risk-resisting ability of enterprise information systems and reduce the loss risk of important data, there is a very urgent need for Zhejiang electric power company to construct a safe and reliable data-level disaster recovery center. On the basis of in-depth analysis of existing disaster recovery technologies, for the Zhejiang electric power marketing business application system example, this paper takes its situations into consideration and successfully constructs its corresponding disaster recovery system using the remote mirror technology. The system achieves data level disaster recovery goals with no data loss and no delay. Practical experience will be helpful for further construction works of the global disaster recovery system.