二冷配水优化对连铸坯质量改善的影响  被引量:4

Effect of Optimization of Secondary Cooling System on the Quality Improvement of Continuous Casting Slab

在线阅读下载全文

作  者:许少普 

机构地区:[1]南阳汉冶特钢有限公司技术中心钢研所,河南南阳474500

出  处:《连铸》2012年第1期5-8,19,共5页Continuous Casting

摘  要:为满足品种开发与产能提高的需要,南阳汉冶特钢有限公司对原纯水二次冷却系统进行了气雾冷却改造,改造后,在其他条件不变的情况下,含Nb、V、Ti类微合金化钢的表面质量合格率较改造之前的93.8%下降到92.5%。后通过对新投产的二冷配水各区的参数等进行优化调整,该类钢的表面质量合格率由优化前的92.5%提高到优化后的98.81%,取得了理想的效果。In order to develop products and increase production capacity, Nanyang Hanye Special Steel Co Ltd improved secondary cooling system and changed pure water into foggy spray cooling. After the improvement, the qualification rate of surface quality of the microalloyed steel with Nb, V and Ti was increased from 93.8% to 92.5% without changing other conditions. The parameter in different zones of secondary cooling system was optimized and the qualification rate of surface quality was increased from 92.5 % to 98.81 %, achieving desired results.

关 键 词:气雾冷却 微合金化钢 二冷配水 优化调整 

分 类 号:TF777[冶金工程—钢铁冶金]

 