摘 要:采用HNO3-HF-HCl酸体系消解样品,火焰原子吸收光谱法连续测定非金属材质仿真饰品中的铅、镉和镍。优化了仪器工作参数和消解条件,进行了共存离子的干扰试验。方法检出限分别为铅5.7 mg/kg、镉0.3 mg/kg、镍3.5 mg/kg。实际样品测定的相对标准偏差(n=6)为1.6%~5.2%,回收率为86.0%~105.8%。Continuous determination of trace amounts of lead,cadmium and nickel in nonmetal materials of imitation jewelries was developed by FAAS with microwave assisted HNO3-HF-HCl digestion.The working parameters and digestive conditions were optimized.The effects of concomitant ions and precisions were studied.The method detection limits were 5.7,0.3 and 3.5 mg/kg for Pb,Cd and Ni,respectively.The practical samples were determined,the RSDs were 1.6%~5.2%(n=6),and the recoveries of the above elements ranged from 86.0% to 105.8%.