机构地区:[1]湖南大学土木工程学院,长沙410082 [2]香港城市大学建筑系,香港100013
出 处:《建筑结构》2012年第2期148-153,共6页Building Structure
基 金:国家自然科学基金重大研究计划重点项目(90815030)
摘 要:通过对吉林火车站的刚性模型风洞试验研究,得到了在有无周边建筑群干扰下屋盖表面的风压系数等值线图、脉动风压系数与屋盖的升力系数随风向角的变化曲线,对其风压分布特性做了详细的对比分析研究。研究结果表明:大跨屋盖结构表面主要呈现负风压(风吸力),屋盖合力升力系数均为负值。主站楼在迎风区屋檐、悬挑区域及屋面凸起的天窗位置气流分离较大,风压变化明显,出现较大的负风压系数;由于站台雨篷四周开敞,气流流经站台雨篷时较为顺畅,气流分离较小,因而站台雨篷风压系数较小。Based on the wind-tunnel test of rigid model of Jilin Railway Station,the contours of the wind pressure coefficients,the variations of wind pressure coefficients and the lift coefficients of the roof were presented and discussed with and without the surrounding buildings.The characteristics of the wind pressure distributions were analyzed.It was found that negative pressures(suctions) occurred on the long-span roof in general,the values of the lift coefficients of the roof were negative,and high negative pressure coefficients occurred on the eaves,cantilevered roof and the bulge part of the roof on the main station building.Relatively smaller suctions occurred on the platform awnings of the station because of open surrounding configurations there.