RP-HPLC法测定人全血中环孢素的浓度  

Determination of Cyclosporine A Concentration in Whole Human Blood by RP-HPLC

在线阅读下载全文

作  者:宋和梅[1] 

机构地区:[1]连云港市第一人民医院药学部,江苏连云港222002

出  处:《中国药房》2012年第10期899-901,共3页China Pharmacy

摘  要:目的:建立测定人全血中环孢素浓度的方法。方法:采用反相高效液相色谱法,血样经乙醚萃取、正己烷洗涤后进样测定。色谱柱为Nova-pakC18,流动相为乙腈-甲醇-水(30.8∶51.2∶18),流速为1mL·min-1,柱温为55℃,检测波长为210nm。结果:CsA血药浓度在50~1550ng·mL-1范围内线性关系良好(r=0.9999);平均方法回收率为99.90%~102.13%,平均提取回收率为64.27%~66.58%;日内RSD为2.86%~6.08%,日间RSD为2.95%~6.27%。结论:本法快速、灵敏、准确、实用,适合临床环孢素治疗药物监测的需要。OBJECTIVE: To establish a method to determine the concentration of cyclosporine A (CsA) in whole human blood. METHODS: RP-HPLC was adopted. CsA was extracted from whole blood with diethyl ether and the endogenous interference was removed from blood sample with n-hexane. The separation was performed on Nova-pak C18 column with mobile phase consisted of acetonitrile-methanol-water (30.8:51.2:18)at the flow rate of 1 mL.min-1. The temperature of column was set at 55 ℃, and the detection wavelength was 210 nm. RESULTS: The linear range of CsA was 50-1 550 ng.mL-t (r=0.999 9). The average method recovery was 99.90%~102.13% ; the average extraction recovery was 64.27%-66.58%. The intra-day RSD was 2.86%~ 6.08%, and the inter-day RSD was 2.95% ~6.27%. CONCLUSION: The established method is rapid, sensitive, accurate, and practical, and it is suitable for the drug monitoring of CsA in the clinic.

关 键 词:环孢素 反相高效液相色谱法 血药浓度 

分 类 号:R969.1[医药卫生—药理学] R979.5[医药卫生—药学]

 