检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:金忆凡[1] 吉唯峰[1] 乔卫平[1] 黄学东[1] 孙存英[1]
出 处:《物理实验》2012年第1期44-45,共2页Physics Experimentation
基 金:上海交大第20期PRP项目;985教改项目(No.T311450526)
摘 要:以稳态法的实验装置为基础,通过调节加热源的电压保证待测样品及标样的散热盘的散热温度(电压)相同,记下加热盘和散热盘的温度(电压),根据傅里叶导热方程,以及标准样品的导热系数直接获得待测样品的导热系数.该方法避免了传统方法因散热盘散热过程的理论处理及数据读取引入的误差.The comparative measurement of the thermal conductivity was finished directly using the device of stable-state method. The voltage of the heating source was adjusted so that the temperature of the sample cooling plate was the same as that of the reference sample's cooling plate, and then the temperatures of the sample's heating plate and the cooling plate were recorded. According to Fourier heat conduction equation and the thermal conductivity of the reference sample, the thermal conductivity of the sample was derived directly. The new method avoided the errors caused by the theo-retical treatment and the data of heat dissipation in the traditional way.
分 类 号:O551.3[理学—热学与物质分子运动论]
正在载入数据...