两相热压缩机冷却方式的比较研究  被引量:1

Comparison study on cooling methods of a two-phase thermocompressor

在线阅读下载全文

作  者:饶俊峰[1] 邱利民[1] 陆军亮[1] 管文洁[1] 戴恩乾[1] 楼盼龙[1] 

机构地区:[1]浙江大学制冷与低温研究所杭州310027

出  处:《低温工程》2012年第1期2-6,共5页Cryogenics

基  金:国家杰出青年科学基金(NO.50825601);国家重点基础研究发展计划项目(2010CB227303)资助

摘  要:基于自行设计研制的中国国内首台两相热压缩机,分别研究了水冷和空气自然冷却两种冷却方式对两相热压缩机性能的影响。研究发现,两相热压缩机对冷却方式非常敏感。该压缩机在0.2 Hz、0.4 Hz、0.6 Hz和0.8 Hz频率下运行时,采用水冷时,压比基本上保持不变,即使加热功率达到220 W;但采用空气自然冷却时,压比达到5.0以上,且加热功率不超过140 W。Based on the first self-developed two-phase thermocompressor domestically, the effects of water cooling and air cooling on thermocompressor performance were investigated comprehensively. The re- sults suggest that the whole performance is sensitive to cooling methods. At 0.2 Hz, 0.4 Hz, 0.6 Hz and 0.8 Hz, the pressure ratio is almost constant up to a heating power of 220 W when water cooling was adopt- ed ; while using the air cooling method, the pressure ratio reachs above 5.0 with the heating power less than 140 W.

关 键 词:两相热压缩机 水冷 自然冷却压比 

分 类 号:TB652[一般工业技术—制冷工程]

 