检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:袁川[1] 刘俊勇[2] 张国松[2] 吴磊[1] 龚薇[2]
机构地区:[1]四川省电力公司,四川成都610041 [2]四川大学电气信息学院,四川成都610065
出 处:《四川电力技术》2012年第1期48-53,共6页Sichuan Electric Power Technology
摘 要:电网全部或部分因故障停运后,采用黑启动方案,通过系统中具有自启动能力的机组带动无自启动能力的机组,可实现整个电网的恢复。分析了黑启动过程中的关键问题,对东西关电厂作为黑启动电源的可行性进行了理论分析,并对不同类型的水电机组作为黑启动电源的优劣进行了比较。最后通过PSCAD仿真和试验,验证了东西关电厂作为黑启动电源的可行性。Taking use of black-start program,the generators with self-starting capability are used to drive the generators without self-starting capability to enable the recovery of the entire grid after the whole or part of power outage due to the fault.The key problems in the process of black start are analyzed,and a theoretical analysis for the feasibility of Dong Xiguan power plant being a black start source is carried out.The merits and demerits of different types of water turbine as black start source are compared.Finally,PSCAD/EMTDC is used for simulation,which proves the feasibility of Dong Xiguan power plant as a black start source.
分 类 号:TM732[电气工程—电力系统及自动化]