作 者:胡凤妹[1] 刘国[1] 汤景鹏[1] 陈韶华[2] 檀丽丽[1]
机构地区:[1]地质灾害防治与地质环境保护国家重点实验室(成都理工大学),四川成都610059 [2]四川大学化工学院,四川成都610065
出 处:《环境科学与管理》2012年第2期81-83,110,共4页Environmental Science and Management
摘 要:采用电-芬顿、芬顿-微电解、三维电催化、微电解工艺对预处理双甘膦废水的效果进行了比较研究。试验结果表明:对于高浓度有机磷双甘膦废水,采用上述四种工艺处理后的总磷去除率分别为66.2%、88.1%、87.8%、92.2%。铁碳微电解除磷效果最优,进一步对其影响因素进行试验,结果表明:pH为3,反应时间为2h,铁碳比为1:1时微电解法对双甘膦废水的总磷去除率可达92.2%,微电解联用对废水总磷去除率为96.8%。Electro-Fenton,Fenton micro-electrolysis process,Multi-dimensional electro-catalytic process and micro-electrolysis process have been used for the comparative study of PMIDA wastewater pre-treatment effects.The result showed that the total phosphorus(TP) removal rate for high PMIDA concentrations wastewater were 66.2%,88.1%,87.8% and 92.2% respectively by using four process mentioned above.The TP removal effect of micro-electrolysis process was best,so its results were further tested.The result showed that when pH value was 3,reaction time was 2h and iron and charcoal volume ratio was 1:1,the TP removal rate was 92.2% by using micro-electrolysis process.The TP removal rate of was 92.2% by using two micro-electrolysis processes.
关 键 词:电化学法 双甘膦废水 除磷 铁碳微电解 三维电催化
分 类 号:X703.1[环境科学与工程—环境工程]