On-line Preconcentration and Determination of Trace Metals in Water Samples by Flow Injection Combined with Flame Atomic Absorption Spectrometry via Calix[4]arene Carboxylic Acid Packed Micro-column  被引量:1

On-line Preconcentration and Determination of Trace Metals in Water Samples by Flow Injection Combined with Flame Atomic Absorption Spectrometry via Calix[4]arene Carboxylic Acid Packed Micro-column

在线阅读下载全文

作  者:GUO Da-wang, ZHAO Xiao-wei, JIA Qiong and ZHOU Wei-hong College of Chemistry, Jilin University, Changchun 130012, P. R. China 

出  处:《Chemical Research in Chinese Universities》2012年第1期26-30,共5页高等学校化学研究(英文版)

基  金:Supported by the Fund of State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemi-stry, Chinese Academy of Sciences(No.RERU2011006)

摘  要:An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples.An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples.

关 键 词:arene carboxylic acid PRECONCENTRATION Flow injection Metal ion Flame atomic absorptionspectrometry(FAAS) 

分 类 号:O621.2[理学—有机化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象