检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]南昌大学信息工程学院电气与自动化系,江西南昌330031 [2]随州市供电公司,湖北随州441300
出 处:《电力系统保护与控制》2012年第6期113-118,共6页Power System Protection and Control
摘 要:电压稳定已经被称为负荷稳定,为了研究负荷特性对电压稳定问题的影响,对一种负荷模型下的在线电压稳定性问题进行了研究。提出了一种基于时间断面上的局部等效方法,在所要研究的节点处,把电力网络局部等效成两节点系统,利用PMU测得的电压和电流相量,求出局部等效模型的参数。采用静态ZIP模型导出节点电压稳定指标表达式,可以较好评估系统的静态电压稳定性。通过对标准系统的测试,表明此方法得到的指标线性度更好,精度更高。Voltage stability is called load stability. In order to research the effect of load characteristics on voltage stability, accordingly, online voltage stability of a type of load model is researched. This paper puts forward a local equivalent method which is based on time section. For a researched node, the power grid is equivalent to a two-node system which is composed of a load and a power generation, and the local equivalent model parameters are worked out by using PMU measured voltage and current phasor. Taking static ZIP model as load model, voltage stability index expression is derived, which will be better to evaluate static voltage stability of system. The test about standard system shows that index has better linearitv and higher orecision by this method.
关 键 词:电力系统 电压稳定 静态负荷 电压指标 负荷特性
分 类 号:TM712[电气工程—电力系统及自动化]