检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国矿业大学环境与测绘学院,徐州221008 [2]徐州国祯水务运营有限公司,徐州221008
出 处:《环境工程学报》2012年第3期878-882,共5页Chinese Journal of Environmental Engineering
基 金:中国矿业大学科技基金资助项目(OP080268)
摘 要:设计并利用在差压仪中密闭投加基质的实验方法,根据ASM模型中自养菌和硝化过程耗氧速率的关系,对比研究了ECOSUNIDE工艺和其他4个污水处理厂曝气池混合液中自养菌的浓度。研究表明,在不考虑自养菌增长和衰减情况下,ECOSUNIDE工艺混合液自养菌生物浓度为48.15 mg COD/L,该结果显著高于其他受试污水处理厂的混合液自养菌生物浓度(17.2~37.5 mg COD/L),表明ECOSUNIDE工艺在提高活性污泥中自养菌生物浓度上有较强的优势。设计的实验方法可以简便、有效地测定用于ASM模型中的自养菌浓度。Using a sealed manometric respirometer testing system which was designed by the authors,based on the activated sludge models(ASMs),the autotrophic biomass of activated sludge in 5 different wastewater treatment plants(WWTPs) were tested and studied.The results show that the autotrophic biomass(48.15 mg COD/L) in ECOSUNIDE process was higher than another 4 WWTPs(17.2~37.5 mg COD/L).The study shows that the ECOSUNIDE process can increase the biomass of autotrophic bacteria in activated sludge effectively.
关 键 词:自养菌浓度 硝化速率 ECOSUNIDE 差压仪
分 类 号:X703[环境科学与工程—环境工程]