沥青混合料保温箱的传热分析及改进  被引量:3

Thermal Transmission Analysis and Improvement of Insulation Case for Asphalt Mixture

在线阅读下载全文

作  者:胡碧阳[1] 曹婷[1] 赵悟[1] 张丽梅 

机构地区:[1]长安大学道路施工技术与装备教育部重点实验室 [2]河南路太养路机械股份有限公司

出  处:《工程机械》2012年第3期36-39,99,共4页Construction Machinery and Equipment

摘  要:以某沥青混合料保温箱为例,对其进行传热分析,并用FLUENT软件建立仿真模型。仿真结果表明:该保温箱对冷混合料加热效率较低,加热均匀性差。针对存在的问题,进行改进,改进后该保温箱的加热效率和加热均匀性得到提升,降低了能源的消耗。A certain insulation case for asphalt mixture has been set as the example and analyzed, whose simulation model has also been established with the software FLUENT. The result showed that when heating cold mixture, the heat efficiency and evenness of this insulation case are poor. Focusing on this problem, this box has been improved so as to promote the heating efficiency and evenness, while reducing the energy consumption.

关 键 词:沥青混合料保温箱:传热分析 FLUENT 改进 

分 类 号:U415.5[交通运输工程—道路与铁道工程]

 