检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王冬梅[1] 董谢平[2] 王尚城[1] 王成焘[1]
机构地区:[1]上海交通大学机械与动力工程学院,生物医学制造与生命质量工程研究所,上海200240 [2]江西省人民医院骨科,南昌330006
出 处:《医用生物力学》2012年第1期32-39,共8页Journal of Medical Biomechanics
基 金:国家科技支撑计划课题(2008BAI68B06);上海交通大学“医工(理)交叉研究基金”项目(YG2010MS09)
摘 要:目的利用三维有限元法研究髋部护具对人体股骨-骨盆复合体在侧向冲击载荷作用下生物力学响应的影响。方法基于中国力学虚拟人模型库建立股骨-骨盆-软组织复合体的三维有限元模型,包括皮质骨、松质骨和软组织,并在此基础上建立髋部护具和股骨-骨盆-软组织复合体系统的三维有限元模型;同时,在两个模型中构建刚体平面仿真地面。约束地面刚体,对两个模型均施加侧向2 m/s的速度载荷,整个仿真分析时间设定为20 ms。通过三维有限元分析计算获得两模型受侧向冲击载荷过程中应力、应变变化特性,对比分析髋部护具对股骨-骨盆复合体生物力学响应的影响。结果髋部护具使股骨-骨盆复合体在侧向冲击载荷作用下的应力峰值出现时间提前4 ms以上,且应力应变水平出现大幅度降低;皮质骨上的应力峰值降低67.88%以上,松质骨上的峰值应力下降69.34%以上,松质骨上的压缩主应变峰值降低可达63%。结论在侧向冲击载荷作用下,髋部护具对股骨-骨盆复合体具有良好的保护作用,能够有效预防骨折的发生或降低骨折风险。Objective To investigate the effect of hip protector on biomechanical response of the human pelvis-femur complex under lateral pelvic impacts during sideways falls using three dimensional(3D) finite element(FE) method.Methods Based on the model database of China Mechanical Virtual Human,a 3D FE model of the pelvis-femur-soft tissue complex including cortical bone,cancellous bone and soft tissue capsule and the pelvis-femur-soft tissue complex with a two-layer hip protector were created,respectively.The rigid plane model was also constructed in the two models for ground simulation and constrained in all freedoms.The average hip lateral impact velocity of 2 m/s was applied to the two models,and the time for simulation analysis was set at 20 ms.The stress and strain distribution on the two models under lateral impacts could be obtained by the 3D FE calculation.The comparative analysis was performed to study the effect of the hip protector on biomechanical response of the pelvis-femur complex.Results The hip protector made the peak Von Mises stress appeared 4 ms more earlier in the pelvis-femur complex with a significant decrease in the stress and strain level.The average Von Mises stress peak was decreased by 67.88% and 69.34% in the cortical bone and in the cancellous bone,respectively,and the compressive principal strain peak was decreased by 63%.Conclusions Under lateral pelvic impacts,the two-layer hip protector could act as safeguard for pelvis-femur complex,thus effectively prevent the occurrence or reduce the risk of bone fracture.
关 键 词:股骨-骨盆复合体 侧摔 髋部护具 生物力学响应 有限元分析
分 类 号:R318.01[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222