检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:孙红英[1]
机构地区:[1]广州有色金属研究院分析测试中心,广州市510651
出 处:《光谱实验室》2012年第2期992-995,共4页Chinese Journal of Spectroscopy Laboratory
摘 要:采用直读光谱分析法测定高锰钢中锰含量,建立分析方法,并对锰测定值的不确定度分项进行了评估。结果表明,影响测量结果的主要不确定度分量为:校准曲线的不确定度、标样定值的不确定度、标准样品测量过程所产生的不确定度及样品测量过程随机性的不确定度,控制影响不确定度的主要因素,可以减少测量不确定度,保证分析结果的准确性,该方法也适合高锰钢中其他元素的评定。The method for the determination of Mn in high manganese steel by photoelectric direct reading spectrometry was established,and the uncertainty in the determination of Mn was evaluated.The results showed that the working curve,standard value and randomicity of analysis process for standard and measured samples had a great influence on the determination.Therefore,the control on the above key factors can effectively reduce the uncertainty and ensure the analytical results more accurate.The method also suits for the determination of other elements in high manganese steel.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30