微波-Fenton-活性炭法降解有机磷农药混合废水试验研究  被引量:11

Experimental study on the treatment of organophosphorus pesticide mixed wastewater by microwave-Fenton-activated carbon process

在线阅读下载全文

作  者:李亚峰[1] 春艳 张晓宁[1] 李辉洋[1] 

机构地区:[1]沈阳建筑大学市政与环境工程学院,辽宁沈阳110168

出  处:《工业水处理》2012年第3期45-47,51,共4页Industrial Water Treatment

基  金:辽宁省重点实验室开放基金资助项目(HJ200703);辽宁省教育厅科技攻关项目(2009A600)

摘  要:采用微波-Fenton-活性炭组合工艺对有机磷农药混合废水进行处理。研究了废水初始浓度、初始pH、FeSO4.7H2O及H2O2投加量、微波功率及辐照时间等因素对处理效果的影响。结果表明:在一定的试验条件下,对100 mL COD为360~400 mg/L的废水,当pH为3.5,活性炭投加量为3.0 g,FeSO4.7H2O投加量为0.25 g,30%H2O2投加量为1 mL,微波功率为680 W,辐照时间为7 min时,处理后的出水COD可降至40~44 mg/L,COD去除率平均达89%。Microwave-Fenton-activated carbon combined process has been used for treating organophosphorus pesticides mixed wastewater. The effects of the initial concentration, initial pH, dosages of FeSO4· 7H20 and H202, microwave power and microwave irradiation time,etc, on organophosphorus degradation effectiveness are studied. Under certain experimental conditions, 100 mL of wastewater whose COD is 360-400 mg/L is treated, when its pH is 3.5, dosage of activated carbon 3.0 g, dosage of FeSO4·7H2O 0.25 g, dosage of 30% of H2O2 1 mL, microwave power 680 W and irradation time 7 min ,the treated effluent COD can be dropped to 40-44 mg/L and the average removal rate of COD reaches 89%.

关 键 词:微波-Fenton-活性炭组合工艺 有机磷农药混合废水 氧化乐果 敌敌畏 

分 类 号:X703.1[环境科学与工程—环境工程]

 