乳腺癌超声造影特征分析  被引量:19

Characteristics of breast neoplasms on contrast-enhanced ultrasonography and its clinical value

在线阅读下载全文

作  者:钱小霞[1] 司芩[1] 钱晓莉[1] 张茂红[2] 黄声稀[1] 黄艳丽[1] 

机构地区:[1]安徽医科大学临床学院解放军第八一医院特诊科,南京210002 [2]安徽医科大学临床学院解放军第八一医院乳腺外科,南京210002

出  处:《中华超声影像学杂志》2012年第3期217-219,共3页Chinese Journal of Ultrasonography

基  金:基金项目:南京军区科技攻关项目A类(10MA045)

摘  要:目的探讨乳腺癌超声造影特征及其临床价值。方法对常规超声不能确诊的225例乳腺肿块患者进行超声造影检查,观察造影后显像特征,并与病理结果相比较。结果乳腺恶性肿瘤的特征性表现多为病灶最大直径测值明显大于造影前(P〈0.05).外形不规则,灶内造影剂分布不均匀,局部充盈缺损,局部造影剂滞留;血管走形扭曲,部分呈团块状,可见穿隔血管并呈快进快出。其中局部充盈缺损及造影剂廓清滞留的敏感度和特异度分别为89.0%和91.8%及93.4%和92.5%。结论超声造影对乳腺癌的诊断与鉴别诊断具有重要的临床价值。Objective To investigate the characteristics of breast neoplasms on contrast-enhanced ultrasonography(CEUS) and its clinical value. Methods Two hundred and twenty-five patients with breast masses unable to be diagnosed by conventional ultrasonography were examined with CEUS. The characteristics of these masses on CEUS were analyzed and compared with the results of pathology examination. Results The typical features of breast cancers on CEUS were enlarged maximum diameter of the lesions on CEUS compared to pre-contrast ( P 〈0.05), irregular shapes, heterogeneous distribution of contrast enhancement with perfusion defect or local retention of contrast signals, tortuous, massive or penetrating vessels rapidly entering and exporting from the lesions. The sensitivity and specificity of perfusion defect for breast cancer on CEUS were 89.0% and 91.8%, respectively; the sensitivity and specificity of local retention of contrast signals for breast cancer on CEUS were 93.4% and 92.5%, respectively. Conclusions It is valuable for CEUS in the diagnosis and differential diagnosis of breast neoplasms clinically.

关 键 词:超声检查 微气泡 乳腺肿瘤 

分 类 号:R445.1[医药卫生—影像医学与核医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象