作 者:白真权[1] 赵新伟[1] 罗金恒[1] 路民旭[1] 邸超[2] 李建平[2] 井一平[3] 孙建刚[3]
机构地区:[1]中国石油天然气总公司石油管材研究所 [2]塔里木石油勘探开发指挥部 [3]新疆石油管理局油气储运公司
出 处:《油气储运》2000年第3期28-31,共4页Oil & Gas Storage and Transportation
摘 要:统计分析了克乌复线529×7(8)mm管道全线腐蚀缺陷的漏磁检测数据与现场取样管段室内缺陷尺寸测试数据。对腐蚀缺陷在管道全线的分布情况及特征进行了分类统计,并结合室内测试结果,按里程进行了综合分析。将其结果与剩余强度评价结果相结合,为管道防腐层维修和管段的维护提供决策依据,有利于管道的科学管理和运营。The detection data of corrosion defects gained by leakage magnetic detector and laboratory test data ofdefect dimensions of pipe samples, taken on site which picks up on Kelamayi——Wulumuqi parallel oilpipeline (φ529×7(8)mm) ,are statistically analyzed. The distribution of corrosive defects along the whole line and their characteristics have been statistically classified,and a comprehensive analysis on defect frequency/pipeline kilometer has been made,combined with laboratory test results. The authors consider that the final analysis results, which is from the statistics and evaluation report on residual strength of the pipeline,will be helpful for decision making on the rehabilitation of coating or maintenance of pipeline, which is beneficial to the scientific management and operation of the pipeline.
关 键 词:腐蚀检测 缺陷测试 数据分析 漏磁检测 油气管道
分 类 号:TE973.607[石油与天然气工程—石油机械设备] TE985.8