600MW奥里油锅炉过热器和再热器热偏差分析  

Thermal Deviation Analysis of Superheater and Reheater of 600 MW Orimulsion Oil-burning Boiler

在线阅读下载全文

作  者:陈灿 

机构地区:[1]东方电气东方锅炉有限公司,成都611731

出  处:《东方电气评论》2012年第1期16-24,29,共10页Dongfang Electric Review

摘  要:通过对东方锅炉有限公司首台自主设计制造的、国际上目前容量最大的、专门燃烧奥里油的大型锅炉过热器、再热器特性试验,并对过热器、再热器系统热偏差试验结果进行了初步分析。试验表明:东方锅炉首台自主设计制造的600 MW奥里油锅炉各受热面管系布置和热量分配设计合理,在不同运行工况热偏差较小。The 600 MW orimulsion oil-burning boiler, designed and manufactured by Dongfang Boiler Group Co., Ltd ( DBC), is the world's largest capacity orimulsion oil-burning boiler. Performance test of the superheater and reheater of this boiler is carried out. A primary analysis to the superheater and reheater systems' thermal deviation test results is carried out. The tests show that each heating surface's layout and heat distribution of this orimulsion oil-burning boiler ofDBC are welt designed, and the lhermal deviation is small under different operating conditions.

关 键 词:奥里油锅炉 热偏差 过热器 再热器 

分 类 号:TK227[动力工程及工程热物理—动力机械及工程]

 