上海市卢湾区公共场所集中空调通风系统卫生学预警指标研究  被引量:8

Application of Early-Warning Indicators for Pollution Control of Centralized Air Conditioning Ventilation System in Luwan District,Shanghai

在线阅读下载全文

作  者:徐文玺[1] 刘淮玉[1] 吴建华[1] 

机构地区:[1]上海市卢湾区疾病预防控制中心,上海200023

出  处:《环境与职业医学》2012年第3期164-166,170,共4页Journal of Environmental and Occupational Medicine

基  金:上海市卢湾区卫生局资助重点学科建设项目

摘  要:[目的]分析上海市卢湾区公共场所集中空调通风系统潜在的危险因素,探索有效卫生管理要素,为预防空气传播性疾病提供科学依据。[方法]采用分层抽样方法,随机抽取30家公共场所开展专项问卷调查,并根据《公共场所集中空调通风系统卫生规范》、《公共场所集中空调通风系统卫生学评价规范》开展检测评价。[结果]公共场所卫生应急预案及卫生学检测评价报告匮乏。70.0%场所新风口与污染源距离过近,仅6.7%场所集中空调通风系统风箱安装空气净化消毒装置,未有场所安装冷却塔除雾器或除水器控制气溶胶。冷却水检测嗜肺军团菌阳性率为70.0%,主要菌型为Lp1型;冷却水嗜肺军团菌阳性水样电导率平均值为(5897.55±601.16)μs/cm,阴性水样电导率平均值为(9031.12±1172.35)μs/cm,差异具有统计学意义(t=-2.571,P<0.05)。[结论]冷却水军团菌监测预警可考虑采取电导率等相关指标进行快速检测,同时应控制新风污染及气溶胶扩散,及时开展清洗评价等污染控制工作。[Objective] To analyze the potential risk factors of hygienic situation of centralized air ventilation system in public venues in Luwan District of Shanghai,to explore the key elements for effective management,and to provide scientific basis for airborne disease prevention.[Methods] A total of 30 public venues were chosen by stratified sampling for a questionnaire survey.Assessments were carried out under Hygienic standard for centralized air conditioning ventilation system in public places and Hygienic assessment criterion of cleaning and disinfection of centralized air conditioning ventilation systems in public places.[Results] The selected public venues did not make health emergency plans nor provid regular hygienic evaluation reports.The survey found that 70.0% fresh air inlets were close to pollution sources,only 6.7% places installed air purification and disinfection devices,and none of them were equipped with cooling tower demisting to control aerosols.The cooling water test showed that the positive rate of Legionella pneumophila was 70.0% and the common type was Lp1.The average conductivity of the positive water samples was(5 897.55±601.16) μs/cm and that of the negative was(9 031.12±1 172.35) μs/cm(t=-2.571,P 0.05).[Conclusion] Indicators such as conductivity could be considered to identify Legionella pneumophila in cooling water for pre-warning of pollution.The management essentials of centralized air conditioning ventilation systems in public venues are the control of fresh air pollution and aerosol spread,as well as regular cleaning work and evaluation.

关 键 词:集中空调通风系统 预警指标 管理要素 

分 类 号:R126.4[医药卫生—环境卫生学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象